Search

Optional Letters for Enhanced Access and Test Condition Specificity

Optional additional letters (A-D) specify enhanced human access protection, while supplementary letters (H, M, S, W) define critical testing conditions and intended application.

The IP Code allows for the inclusion of two sets of optional letters that modify or add context to the core protection rating.

Additional Letters (A, B, C, D): Protection against access to hazardous parts. These letters are used if the actual protection against access is higher than that indicated by the first characteristic numeral (IPXX). Alternatively, if only access protection is indicated, the first characteristic numeral is replaced by ‘X’.

  • A: Protected against access with the back of the hand (50 mm sphere probe).
  • B: Protected against access with a finger (jointed test finger).
  • C: Protected against access with a tool (2.5 mm rod, 100 mm length).
  • D: Protected against access with a wire (1.0 mm wire, 100 mm length). For letters C and D, the probe may penetrate its full length, but the stop face must not pass through the opening. For example, IP23CS shows access protection C (tool) which is higher than the protection offered by numeral 2 (finger).

Supplementary Letters (H, M, S, W): Additional information. These letters clarify the operational state or environment under which the protection level was verified.

  • H: High-voltage apparatus.
  • M: Tested for harmful effects due to water ingress when movable parts (e.g., rotor) are in motion.
  • S: Tested for harmful effects due to water ingress when movable parts are stationary.
  • W: Suitable for use under specified weather conditions and provided with additional protective features.

The absence of letters S and M implies that the degree of protection should hold regardless of whether parts are in motion or not, potentially requiring testing under both conditions. If multiple supplementary letters are used, they must be placed in alphabetical sequence.

Related Articles

Immersion protection (IPX7/8) relies on static pressure resistance, with IPX8 test conditions requiring prior agreement and being more severe than temporary immersion (IPX7).

Second Characteristic Numeral 7 and 8: Immersion Protection and Multiple The degrees of protection IPX7 and IPX8 address the capability of an enclosure to withstand the static pressure and saturation effects of being submerged in water. It is critical to understand the rule governing versatility: an enclosure designated IPX9 only is considered unsuitable for exposure…

IPX5 and IPX6 classify resistance to direct, pressurized water streams, distinguished by the nozzle size and flow rate used during testing

Second Characteristic Numeral 5 and 6: Pressurized Water Jet Tests Degrees IPX5 and IPX6 define the enclosure’s capability to withstand forceful water jets, simulating conditions like hosing down. Both tests utilize a standard hose nozzle (Figure 6) and require spraying the enclosure from all practicable directions. The water pressure is adjusted solely to achieve the…

The first characteristic numeral (1-4) simultaneously classifies protection against human access using specific probes and against the physical ingress of similarly sized solid objects

The first characteristic numeral (1 through 4) always implies the satisfaction of two conditions simultaneously: protection of persons against access to hazardous parts, and protection of the equipment against the ingress of solid foreign objects. This dual role ensures both operational safety and physical integrity against external contamination. The definitions for protection against access rely…

IEC60529 Brief Introduction to IP Code

The IP Code is a coding system designed to indicate the degrees of protection provided by enclosures against access to hazardous parts, ingress of solid foreign objects, and ingress of water . It consists of the letters “IP” followed by two characteristic numerals, with optional additional and supplementary letters . The first numeral (0-6) indicates protection…

The IEC 60529 standard establishes a unified classification system for enclosure protection against three primary hazards, applicable up to 72.5 kV

The standard IEC 60529 describes a system for classifying the degrees of protection provided by enclosures for electrical equipment. This system is generally suitable for most electrical equipment, provided the rated voltage does not exceed 72.5 kV. The fundamental objective of this standard is multi-faceted: to provide definitions for degrees of protection, establish designations for…